Soil Temperature and Humidity Sensing

Requirement Identifier C_M_F_soilTempAndHumiditySensing

Name: Soil Temperature and Humidity Sensing

Text: The Station Module of the PlanCTTM System shall be able to measure the following soil parameters:

Required technical parameters:
  • Stock temperature: > -40 Grad Celsius .. < +125 Grad Celsius
  • Operating temperature: > -25 Grad Celsius .. < +85 Grad Celsius
  • Measurement range for soil moisture (volumetric water content, [m3/m3]): > 0,05 .. < 0,5
  • Measurement range (soil temperature): > -25 Grad Celsius .. < +85 Grad Celsius
  • Measurement depth: < 600mm
  • Maximal mass: 200 g
  • Standard deviation error (soil temperature): < 5 %
  • Standard deviation error (soil moisture): < 5 %
  • Accuracy (soil temperature): standard deviation error + max. 5 % of the measured value
  • Accuracy (soil moisture): standard deviation error + 1 %
  • Resolution (soil moisture): (in case of digitalized output): min 10 bit
  • Resolution (soil temperature): (in case of digitalized output): min 10 bit

Rationale: These measured parameters serve as inputs for the DSM and the user may also be interested in real time soil data.

Level | Type | Subtype: Component | Mandatory | Functional Requirement

Source: Confirmed and well-tried market consideration: users are looking for monitoring systems with soil sensing capabilities (Hlaszny dr., Edit)

Creation Date: 2016/01/04 16:38

Importance: 6 of 10

Verification/Validation Method: <tbd>

Verification/Validation Status: not yet in progress

Note: The requirement has been taken over from the Confluence-entries: SMAR-1121, SMAR-1123, SMAR-1127.

See Also: Stakeholder Requirement Sensed Data from Plants