Temperature grade

Requirement Identifier P_M_R_temperatureGrade

Name: Temperature grade

Text: All of the components used in the PlanCT TM System shall be graded for one of the following operating temperature ranges:

Rationale: With direct sunlight the inner temperature of the enclosure can easily reach up to 60 degrees of Celsius. Subzero temperatures are also possible in the winter season.

Level | Type | Subtype: Part Requirement | Mandatory | Environmental Requirement

Source: All components with narrower operating temperature range are inadequate for outdoor applications. (Nemeth, Peter)

Creation Date: 2016/03/22 13:08

Importance: 8 of 10

Verification/Validation Method: This parameter shall be verified by using the datasheets of the components.

Verification/Validation Status: not yet in progress

Note: n/a

See Also: n/a